Metric Dimension
Model | H Tube Size | K | A | B | C | D | E | G | I | J | X | Y | Effective Area (mm2) | Weight (g) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TL4-M3M | 4 | M3x0.5 | 18.4 | 16.1 | 12.2 | 16.4 | 8.3 | 12.9 | 8 | 9.2 | 7.8 | 9.8 | 1.3 | 3 |
TL4-M5M | M5x0.8 | 18 | 15.1 | 11.2 | 2.2 | 3.3 | ||||||||
TL4-M6M | M6x1.0 | 18.9 | 3.9 | 3.6 | ||||||||||
TL4-01M | RC1/8 | 20.9 | 16.9 | 13 | 10 | 10.5 | 4.8 | 6.2 | ||||||
TL6-M5M | 6 | M5x0.8 | 20.3 | 17.5 | 12.4 | 17.1 | 10.6 | 13.5 | 8 | 9.2 | 9.8 | 11.8 | 3.5 | 4 |
TL6-M6M | M6x1.0 | 21.2 | 3.6 | 4.3 | ||||||||||
TL6-01M | RC1/8 | 23.5 | 19.5 | 14.2 | 10 | 11.5 | 8.5 | 6 | ||||||
TL8-01M | 8 | RC1/8 | 28.4 | 24.4 | 17.1 | 23.1 | 14.5 | 18.8 | 10 | 11 | -- | -- | 17.2 | 10 |
TL8-02M | RC1/4 | 30.5 | 24.5 | 17.2 | 14 | 15 | 17.8 | 15.5 | ||||||
TL8-03M | RC3/8 | 31.4 | 24.9 | 17.6 | 17 | 18.5 | 22.5 | |||||||
TL8-04M | RC1/2 | 36.4 | 28.4 | 21.1 | 21 | 23 | 37 | |||||||
TL10-01M | 10 | RC1/8 | 32.4 | 28.4 | 19.6 | 27.1 | 17.5 | 21.2 | 15 | 16 | -- | -- | 22.4 | 17 |
TL10-02M | RC1/4 | 35.3 | 29.3 | 20.5 | 34 | 20 | ||||||||
TL10-03M | RC3/8 | 35.9 | 29.4 | 20.6 | 17 | 18.5 | 24 | |||||||
TL10-04M | RC1/2 | 39.9 | 31.9 | 23.1 | 21 | 23 | 39 | |||||||
TL12-01M | 12 | RC1/8 | 35.7 | 31.7 | 21.3 | 29.7 | 20.8 | 23.6 | 15 | 16 | -- | -- | 34 | 20.5 |
TL12-02M | RC1/4 | 38.6 | 32.6 | 22.2 | 38 | 23 | ||||||||
TL12-03M | RC3/8 | 39.2 | 32.7 | 22.3 | 17 | 18.5 | 49 | 27.5 | ||||||
TL12-04M | RC1/2 | 43.2 | 35.2 | 24.8 | 21 | 23 | 42.5 |
Q1: How does TL differ from UL and TLL?
A: TL is an L-type elbow with one push-in tube port and one male thread. UL has two push-in ports (no thread). TLL is functionally the same as TL but with an extended body to clear recesses/obstructions.
Q2: Which tube sizes/materials are supported?
A: 4–12 mm PU and nylon (PA) tubes; match tube OD to the fitting size for proper sealing.
Q3: What threads and sealing are provided?
A: M3/M5/M6/RC1/8–RC1/2 (BSPT). Threads are factory pre-sealed; PTFE tape is typically unnecessary unless the sealant has been worn by repeated servicing.
Q4: What is the recommended installation sequence?
A: Tighten the threaded end first (wrench the hex to seat and orient) → square-cut with a PU tube cutter → push fully to the stop → perform a pull test → leak test.
Q5: Is it reusable?
A: Yes—provided the O-ring and metal collet are intact. Re-cut scratched/ovalized tube ends before reinsertion.
Q6: Operating limits?
A: 0–0.9 MPa, 5–60 °C. Avoid aggressive chemicals and long-term oil immersion; verify compatibility for special media.
Q7: How to address minor leakage?
A: Ensure full insertion and pull-test, check for clean, square tube ends, and remove debris near the collet/O-ring. Replace a short section of tubing if necessary and re-test.
Q8: Mini vs. standard elbows?
A: The mini version is ~40% smaller and ~20% slimmer, enabling dense layouts and tight corners while maintaining smooth flow and airtight performance.