Metric Dimension
| Model | H Tube Size | K | A | B | C | D | E | G | I | J | X | Y | Effective Area (mm2) | Weight (g) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TL4-M3M | 4 | M3x0.5 | 18.4 | 16.1 | 12.2 | 16.4 | 8.3 | 12.9 | 8 | 9.2 | 7.8 | 9.8 | 1.3 | 3 |
| TL4-M5M | M5x0.8 | 18 | 15.1 | 11.2 | 2.2 | 3.3 | ||||||||
| TL4-M6M | M6x1.0 | 18.9 | 3.9 | 3.6 | ||||||||||
| TL4-01M | RC1/8 | 20.9 | 16.9 | 13 | 10 | 10.5 | 4.8 | 6.2 | ||||||
| TL6-M5M | 6 | M5x0.8 | 20.3 | 17.5 | 12.4 | 17.1 | 10.6 | 13.5 | 8 | 9.2 | 9.8 | 11.8 | 3.5 | 4 |
| TL6-M6M | M6x1.0 | 21.2 | 3.6 | 4.3 | ||||||||||
| TL6-01M | RC1/8 | 23.5 | 19.5 | 14.2 | 10 | 11.5 | 8.5 | 6 | ||||||
| TL8-01M | 8 | RC1/8 | 28.4 | 24.4 | 17.1 | 23.1 | 14.5 | 18.8 | 10 | 11 | -- | -- | 17.2 | 10 |
| TL8-02M | RC1/4 | 30.5 | 24.5 | 17.2 | 14 | 15 | 17.8 | 15.5 | ||||||
| TL8-03M | RC3/8 | 31.4 | 24.9 | 17.6 | 17 | 18.5 | 22.5 | |||||||
| TL8-04M | RC1/2 | 36.4 | 28.4 | 21.1 | 21 | 23 | 37 | |||||||
| TL10-01M | 10 | RC1/8 | 32.4 | 28.4 | 19.6 | 27.1 | 17.5 | 21.2 | 15 | 16 | -- | -- | 22.4 | 17 |
| TL10-02M | RC1/4 | 35.3 | 29.3 | 20.5 | 34 | 20 | ||||||||
| TL10-03M | RC3/8 | 35.9 | 29.4 | 20.6 | 17 | 18.5 | 24 | |||||||
| TL10-04M | RC1/2 | 39.9 | 31.9 | 23.1 | 21 | 23 | 39 | |||||||
| TL12-01M | 12 | RC1/8 | 35.7 | 31.7 | 21.3 | 29.7 | 20.8 | 23.6 | 15 | 16 | -- | -- | 34 | 20.5 |
| TL12-02M | RC1/4 | 38.6 | 32.6 | 22.2 | 38 | 23 | ||||||||
| TL12-03M | RC3/8 | 39.2 | 32.7 | 22.3 | 17 | 18.5 | 49 | 27.5 | ||||||
| TL12-04M | RC1/2 | 43.2 | 35.2 | 24.8 | 21 | 23 | 42.5 |
Q1: How does TL differ from UL and TLL?
A: TL is a 90° elbow with one push-in tube port and one male thread. UL has two push-in ports (no thread). TLL is an extended TL for clearing recesses/obstructions.
Q2: What tube sizes/materials are supported?
A: 4–12 mm OD polyurethane and nylon (PA). Match tube OD to the fitting size for proper sealing and grip.
Q3: What thread types and sealing are provided?
A: M3/M5/M6/RC1/8–RC1/2 (BSPT) with factory-applied sealant; PTFE tape is usually unnecessary unless the sealant has been worn by repeated servicing.
Q4: Recommended installation sequence?
A: Tighten/orient the threaded end via the hex → cut the tube end square, deburr, clean/dry → push fully to the stop → pull-check → pressure-hold/leak-test.
Q5: Is it reusable? Any precautions?
A: Yes. Before reinsertion, re-cut a fresh section and keep the tube end square, clean, and dry. Nicks or ovalization can reduce sealing and retention.
Q6: Operating range and media guidance?
A: 0–0.9 MPa, 5–60 °C, primarily for compressed air. Avoid aggressive chemicals, long-term oil immersion, and high temperatures; validate special media on site.
Q7: Any tips for vibrating or moving assemblies?
A: Use nearby tube clamps/tie mounts to shorten unsupported spans and observe the tube's minimum bend radius to reduce fatigue.
Q8: How should I troubleshoot a minor leak?
A: Confirm full insertion with a passed pull-check, verify a clean/square tube cut, and remove any debris near the release ring area. If needed, re-cut and reconnect, then repeat the pressure-hold test.
Q9: What's the key difference vs. the standard TL?
A: TL (MINI) achieves similar flow and sealing performance in a significantly smaller envelope (~40%/~20% reduction), ideal for dense layouts and tight corners.