FAQ
Q1: What kind of equipment is the MC42 Series suitable for?
A: The MC42 Series is suitable for equipment that needs a compact vacuum ejector with a lightweight 10 mm body and concentrated installation layout.
Q2: Can the MC42 Series be used with a digital vacuum sensor?
A: Yes. The MC42 Series supports digital vacuum sensor mounting and selectable sensor configurations.
Q3: Can the MC42 Series be mounted on a manifold?
A: Yes. The series supports manifold mounting with up to 5 units.
Q4: What is the difference between 05 and 07 types?
A: The main differences are nozzle size, vacuum flow, and air consumption. The nozzle sizes are 0.5 mm and 0.7 mm.
Q5: What is the difference between HS and HR?
A: The main differences are nominal pressure and vacuum flow. HS is 0.5 MPa, while HR is 0.38 MPa.
Q6: What solenoid valve air passage types are available?
A: The MC42 Series can be selected with normally closed, normally open, or self-holding solenoid valve air passage types.
Q7: What should be noted when selecting the self-holding type?
A: If the self-holding valve is selected, the energy-saving function of a sensor cannot work.
Q8: Why is the MC42 Series suitable for replacement use?
A: Because it has the same dimensions as the MPV42 switching valve, replacement in an existing system is easier.