Item | Unit | MPS-V23 | MPS-P23 | MPS-R23 | |
---|---|---|---|---|---|
Applicable Fluid | Air (vacuum), non-corrosive gas | ||||
Sensing Element | Sillicon diaphragm | ||||
Set Pressure Range | kPa | -101.0 ~ 0 kPa | -0.1 ~ 1 MPa | -101 ~ 500 kPa | |
Proof Pressure | MPa | 0.3 | 1.5 | 0.8 | |
Ambient Temperature Range | ºC | 0 ~ 50 (No freezing) | |||
Ambient Humidity Range | %RH | 35 ~ 85 (no condensation) | |||
Port Size | R1/8(male), NPT1/8(male), G1/8(male) | ||||
Power Supply Voltage | V | DC12 ~ 24 ± 10%, ripple (Vp-p) less than 10% | |||
Current Consumption | mA | Max. 55 | |||
Net Weight | g | 135 (including cable) |