Q1: What is the CVA-V?
A: The CVA-V is a mechanical vacuum switch for use with the CVA2 ejector.
Q2: What is the pressure range of the CVA-V?
A: The pressure range is -33.3 to -73.2 kPa.
Q3: What is the hysteresis range of the CVA-V?
A: The hysteresis range is 4 to 13.3 kPa.
Q4: What contact type does the CVA-V use?
A: The CVA-V uses a reed type normally open contact arrangement.
Q5: What rated voltages are supported by the CVA-V?
A: It supports AC125V and AC250V.
Q6: What current load ratings does the CVA-V support?
A: It supports 5A at AC125V and 3A at AC250V.
Q7: What are the environmental operating conditions of the CVA-V?
A: The operating ambient temperature is 0 to 60℃, and operating humidity is 35 to 85%RH with no condensation.
Q8: What are the body and cable specifications of the CVA-V?
A: The body mass is 135 g and the cable length is 100 mm.