Metric Dimension
Model | H Tube Size | K | A | E | G | I | J | X | Y | Effective Area | Weight (g) |
---|---|---|---|---|---|---|---|---|---|---|---|
TSM4-M5M | 4 | M5x0.8 | 17.3 | 8 | 11 | 8 | 9.2 | 7.8 | 9.8 | 3.5 | 3.5 |
TSM6-M5M | 6 | M5x0.8 | 18.7 | 10 | 13.2 | 10 | 11.5 | 9.8 | 11.8 | 15.9 | 6.2 |
Q1: How does TSM differ from TS and TSH?
A: TSM is a female M5 mini coupler for direct mating; TS is male-threaded; TSH uses an internal-hex low-profile form for near-flush, dense layouts.
Q2: Are the threads pre-sealed? How should I seal them?
A: No. Apply liquid thread sealant or PTFE tape to the mating male thread per site practice, then pressure-hold and leak-check.
Q3: Which tubing sizes/materials are supported?
A: PU and nylon (PA) in 4 mm and 6 mm OD.
Q4: Recommended installation steps?
A: (1) Wrench the female side via the hex base → (2) Cut square, deburr, clean/dry the tube → (3) Push fully to the stop → (4) Pull-check → (5) Leak-test.
Q5: Can it be reconnected? Is the O-ring replaceable?
A: Reconnection is fine with intact parts. The O-ring is integral and non-replaceable; if leakage or grip loss occurs, replace the entire fitting.
Q6: Any surface prep before assembly?
A: Keep mating threads clean and dry—remove dust, cutting oil, and residues to maximize sealant/PTFE effectiveness.
Q7: What operating environment is intended?
A: General industrial compressed-air service; validate pressure/temperature/vibration against your system and tubing specs.