Metric Dimension
| Model | H Tube Size  |   K  | A | B | C | D | E | G | I | J | X | Y |   Effective Area (mm2)  | Weight (g)  | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TT4-M3M | 4 | M3x0.5 | 19.4 | 17.1 | 13 | 14.2 | 8.3 | 12.4 | 8.0 | 9.2 | 7.8 | 9.8 | 1.4 | 3.9 | 
| TT4-M5M | M5x0.8 | 19.1 | 16.1 | 11.9 | 14.3 | 8.2 | 8.5 | 3.7 | 4.3 | |||||
| TT4-M6M | M6x1.0 | 20 | 16 | 2.8 | 4.5 | |||||||||
| TT4-01M | RC1/8 | 21.9 | 17.9 | 13.7 | 10.0 | 11 | 4.6 | 7.2 | ||||||
| TT6-M5M | 6 | M5x0.8 | 21.3 | 18.3 | 13 | 15.3 | 10.6 | 13 | 8.0 | 8.5 | 9.8 | 11.8 | 3.5 | 5.5 | 
| TT6-M6M | M6x1.0 | 22.2 | 3.6 | 5.8 | ||||||||||
| TT6-01M | RC1/8 | 24.2 | 20.2 | 14.9 | 10.0 | 11 | 8.5 | 8.4 | 
Q1: How does TT (MINI) differ from UT (MINI)?
 A: TT (MINI) uses two push-in + one threaded port for direct mating to valves/bodies; UT (MINI) has three push-in ports for thread-free tube splits.
Q2: Why use the inline main + perpendicular branch?
 A: It keeps the main run straight and the branch clear, shortening tubing, cutting pressure loss, and simplifying maintenance.
Q3: What tubing and sizes are supported?
 A: PU and nylon (PA) in 4 mm and 6 mm OD. Cut square, deburr, clean/dry, then push fully to the stop for airtight seating.
Q4: Do RC-threaded models require PTFE tape?
 A: Typically no—RC threads are factory pre-sealed. After repeated servicing, reapply sealant or add a light PTFE wrap if needed.
Q5: Recommended installation sequence?
 A: Wrench and orient the threaded port → cut square, deburr, clean/dry the tube → push fully to the stop → pull-check → pressure-hold/leak-test.
Q6: Is it reusable?
 A: Yes. Before reinsertion, re-cut a fresh section and keep the tube end clean and square to preserve sealing and retention.
Q7: Operating range & media guidance?
 A: 0–0.9 MPa, 5–60 °C, with clean, dry compressed air; filtration and water removal are recommended for longevity.