| Item | Unit | MPS-V42 | MPS-D42 | MPS-E42 | |
|---|---|---|---|---|---|
| Applicable Fluid | Air, non-corrosive gas, non-flammable gas | ||||
| Sensing Element | Sillicon diaphragm | ||||
| Set Pressure Range | -100 ~ 0 kPa | -2 ~ 2 kPa | -1000 ~ 0 Pa | ||
| Proof Pressure | kPa | 300 | 20 | 3 | |
| Ambient Temperature Range | ºC | 0 ~ 50 | |||
| Ambient Humidity Range | %RH | 35 ~ 85 (no condensation) | |||
| Port Size | M5 (female) x 2 | ||||
| Power Supply Voltage | V | DC12 ~ 24 ± 10%, ripple (Vp-p) ≤ 10% | |||
| Current Consumption | mA | Max. 40 | |||
| Net Weight | Without Cable | g | 27 | ||
| With Cable | 72 | ||||