FAQ
Q1: What is the MPS-81 Series?
A: The MPS-81 Series is a separate type pressure sensor head with the sensor head separated from the display for pressure monitoring at different equipment locations.
Q2: What is the advantage of the separate design?
A: The sensor head can be installed in narrow or distributed locations, while pressure values can be checked centrally from the display.
Q3: How many pressure points can one display manage?
A: With the matching display, one display can manage up to 4 pressure points. A 1-channel display is also available.
Q4: What is the difference between MPS-V81 and MPS-R81?
A: MPS-V81 is the vacuum type with a pressure range of -100 to 0 kPa. MPS-R81 is the compound type with a pressure range of -100 to 500 kPa.
Q5: Is the MPS-81 sensor head suitable for compact spaces?
A: Yes. The MPS-81 sensor head is 10 mm wide, making it suitable for narrow spaces inside equipment.
Q6: What port options are available for MPS-81?
A: M5, Φ4 push-in fitting, and Φ6 push-in fitting options are available, including M5 through-hole, M5 with mounting hole, and M5 universal joint styles.
Q7: What output does the MPS-81 provide?
A: The MPS-81 provides DC1 to 5V analog voltage output for sending pressure signals to the display or control system.
Q8: Which series can the MPS-81 be mounted with?
A: The MPS-81 can be used with SC1 and SC2 series mounting configurations. A common mounting reference is MPS-V81-SC1.