Deflector Cap Relief Valve
- FUJIKURA FRC is a low-pressure atmospheric relief valve with a deflector cap to control blowout direction and reduce foreign matter intrusion.

Deflector Cap Relief Valve
| Item | FRCB (brass body) | FRCT (SUS316 body) |
|---|---|---|
| Complete model numbers | FRCB-☐-V-set pressure | FRCT-☐-V-set pressure |
| Suitable condition | Low-pressure fluid lines requiring controlled blowout direction and external discharge after relief | |
| Pressure resistance | 1.62 MPa | |
| Body material | Brass | SUS316 |
| Cap material | Aluminum alloy with anodized finish | |
| Seal material | FKM, standard | |
| Operating temperature range | According to seal material | |
| Pipe port sizes | R1/8, R1/4, R3/8, R1/2, R3/4 | |
Q1: What is the FUJIKURA FRC Series?
A: The FRC Series is a deflector cap low-pressure atmospheric relief valve that discharges fluid externally when line pressure reaches the set cracking pressure.
Q2: What is the difference between the FRC and FRA Series?
A: FRA is a standard low-pressure atmospheric relief valve. FRC adds a deflector cap to control blowout direction and reduce foreign matter entering the valve.
Q3: Is the FRC Series suitable for outdoor or exposed environments?
A: The deflector cap helps reduce foreign matter intrusion, making the FRC Series suitable for equipment where exposed environments must be considered.
Q4: What body materials are available?
A: Brass and SUS316 body options are available, represented by model codes B and T. Brass bodies are nickel plated.
Q5: What pipe port sizes are available?
A: R1/8, R1/4, R3/8, R1/2, and R3/4 port sizes are available.
Q6: What cracking pressure range is available?
A: The main reference range is 30 to 1000kPa, 30 to 1080kPa. The actual range should be confirmed based on the selected conditions.
Q7: How is the cracking pressure specified?
A: The cracking pressure is specified in kPa and added to the end of the model number, such as FRCB-2-V-300 for a 300kPa setting.
Q8: Can the FRC cracking pressure be adjusted by the user?
A: The cracking pressure is adjusted before shipment, so the required setting pressure should be specified during selection or ordering.
Q9: What should be noted during installation?
A: The outlet must face upward during piping installation to maintain the specified relief and cracking characteristics.
Q10: What applications is the FRC Series suitable for?
A: It is suitable for pressure tank control, low-pressure relief protection, machine tools, industrial furnaces, medical equipment, analyzers, water-treatment equipment, gas generators, and outdoor equipment relief.