TAKEX_FL7314_FL7326

200°C PFA heat- and chemical-resistant liquid level fiber optic unit

  • TAKEX FL7314 and FL7326 are 200°C PFA-covered fiber optic units for liquid level detection in water, oil, and chemicals.
  • They use refractive sensing, provide 1 mm or less repeatability with water, and offer φ6.35 or φ4 sensing tips for different installation requirements.
  • Brand TAKEX Takenaka Engineering Co., Ltd.
Features
  • 200°C heat-resistant sensing: The fiber optic units operate in ambient temperatures up to 200°C for liquid level detection in high-temperature process environments.
  • PFA chemical-resistant construction: The PFA fluoropolymer covering provides heat and chemical resistance for use with water, oil, and a wide range of chemical liquids.
  • Refractive liquid level sensing: Liquid contact is detected through the optical change caused by the difference in refractive index between air and liquid.
  • Two sensing tip sizes: FL7314 uses a φ6.35 cylindrical tip, while FL7326 uses a slimmer φ4 tip for installations with different space requirements.
  • 1 mm or less repeatability: Repeatability is 1 mm or less with water, with −0.1 to +0.5 MPa pressure resistance for liquid level applications.
Specification
ItemSpec.
ModelsFL7314
FL7326
Product typeHeat- and chemical-resistant liquid level fiber optic unit
Detection methodRefractive
Detecting objectLiquid
Applicable liquidsWater, oil, chemicals, etc.
Liquid detectionDetection upon liquid contact
Tip appearanceCylindrical
Environmental featureHeat resistant
FeaturesPFA tube, liquid level detection, heat resistant, chemical resistant
Repeatability1 mm or less with water
Pressure resistance−0.1 to +0.5 MPa
Ambient temperature−40 to +200°C, no condensation inside PFA tube
Fiber optic cable length2.4 m
Allowable bending radiusR50 mm
Fiber covering materialPFA fluoropolymer
Fiber materialGlass
Weight150 g or less
Applicable amplifiersF70AR, F70R, F80R, F85RN

Specification notes

  • Liquid conditions: Colored and colorless transparent liquids can be detected. Sample testing is recommended for liquids with high viscosity or turbidity.
  • Heat-resistant operating conditions: The ambient temperature range is −40 to +200°C. Condensation inside the PFA fluoropolymer tube must be avoided.
  • Fiber bending conditions: The allowable bending radius is R50 mm. Installation and routing should remain within the specified bending limits.
FAQ

Q1: What are TAKEX FL7314 and FL7326?
A: FL7314 and FL7326 are 200°C PFA-covered heat- and chemical-resistant fiber optic units that use refractive sensing for liquid level detection.


Q2: What is the difference between FL7314 and FL7326?
A: The primary difference is the sensing tip size. FL7314 uses a φ6.35 tip, while FL7326 uses a slimmer φ4 tip. Both use 2.4 m fibers and PFA heat- and chemical-resistant construction.


Q3: What is the maximum operating temperature of FL7314 and FL7326?
A: Both models have an ambient temperature range of −40 to +200°C.


Q4: What liquids can FL7314 and FL7326 detect?
A: They can detect water, oil, and a wide range of chemical liquids, including colored and colorless transparent liquids. Sample testing is recommended for highly viscous or turbid liquids.


Q5: How do FL7314 and FL7326 detect liquid level?
A: They use a refractive sensing method that detects the optical change caused by the difference in refractive index between air and liquid.


Q6: What is the repeatability of FL7314 and FL7326?
A: Repeatability is 1 mm or less when detecting water.


Q7: What is the pressure resistance of FL7314 and FL7326?
A: The pressure resistance range is −0.1 to +0.5 MPa.


Q8: What fiber material and length do FL7314 and FL7326 use?
A: Both models use glass fiber with a PFA fluoropolymer covering and a fiber length of 2.4 m. The allowable bending radius is R50 mm.


Q9: Do FL7314 and FL7326 provide NPN or PNP output?
A: No. They are fiber optic sensing units and require a compatible TAKEX fiber amplifier for electrical output.


Q10: What applications are suitable for FL7314 and FL7326?
A: They are suited to liquid level and liquid presence detection in high-temperature process equipment, tanks, and liquid handling systems requiring heat- and chemical-resistant construction.