TAKEX_FU901BC

Pipe liquid level detection fiber optic unit

  • TAKEX FU901BC is an externally mounted fiber optic unit that detects liquid presence at a set level in transparent or translucent pipes with 6–26 mm outer diameters.
  • It uses light refraction, offers 1 mm or better repeatability, and includes a 2 m free-cutting fiber.
  • Brand TAKEX Takenaka Engineering Co., Ltd.
Features
  • Light-refraction liquid level detection: FU901BC detects changes in light refraction between empty and liquid-filled sections of a pipe, enabling non-contact detection of liquid presence at a selected level.
  • Compatible with φ6–26 mm pipes: Designed for transparent or translucent pipes with outer diameters of 6–26 mm and wall thicknesses up to 3 mm, including suitable glass and PFA tubing.
  • Easy external mounting: The compact unit weighs approximately 7 g and mounts to the outside of a pipe using the supplied zip ties, without direct contact with the liquid.
  • Repeatability of 1 mm or less: Provides repeatable point-level detection. Two units can be installed at different heights to monitor upper and lower liquid level limits.
  • Heat-resistant fiber and flexible routing: Features a −40 to +105°C ambient temperature range, a 2 m free-cutting fiber, an R10 (10 mm) allowable bending radius, and an IP50 protection rating.
Specification
ItemSpec.
ModelFU901BC
Product typePipe liquid level detection fiber optic unit
Detection methodLight refraction (dioptric)
Detection objectLiquid
Environmental featureHeat resistant type
Tip appearanceExternal pipe-mount type
Applicable pipeTransparent or translucent pipe
Applicable pipe materialsGlass, PFA, and similar materials
Applicable pipe outer diameterΦ6–26 mm
Applicable pipe wall thickness3 mm max.
Repeatability1 mm or less
Ambient temperature−40 to +105°C
Ambient humidity35–85% RH
Fiber length2 m, free-cutting
Fiber cable diameterΦ1 mm × 2
Allowable fiber bending radiusR10 (10 mm)
Housing materialPolycarbonate
Fiber covering materialCross-linked polyethylene
Fiber core materialPlastic
Protection ratingIP50
WeightApprox. 7 g
Mounting methodZip-tie mounting on outside of pipe
Min. spacing for two separately mounted units15 mm (individual zip-tie mounting)
Min. spacing for adjacent assembled units5 mm (separately supplied M3 countersunk screws required)
Applicable amplifiersF2R, F70R, F70AR, F71R, F80R, F85RN

Specification notes

  • Pipe compatibility and detection conditions: FU901BC is designed for transparent or translucent pipes with outer diameters of Φ6–26 mm and wall thicknesses up to 3 mm. It detects liquid presence through changes in light refraction. Some liquids, including certain milky-white liquids, may not be detectable.
  • Upper and lower level mounting: The unit can be secured to the outside of a pipe using zip ties. Two separately mounted units require a minimum spacing of 15 mm. Adjacent assembly allows 5 mm spacing but requires separately supplied M3 countersunk screws.
  • Fiber routing and operating conditions: The unit includes a 2 m free-cutting fiber with an R10 (10 mm) allowable bending radius. It operates from −40 to +105°C at 35–85% RH and has an IP50 protection rating.
FAQ

Q1: What is TAKEX FU901BC?
A: FU901BC is a pipe liquid level detection fiber optic unit that uses changes in light refraction to detect whether liquid has reached a selected position inside a transparent or translucent pipe.


Q2: What pipe sizes are compatible with FU901BC?
A: FU901BC is designed for pipes with outer diameters of φ6–26 mm and wall thicknesses up to 3 mm.


Q3: What pipe materials can FU901BC be mounted on?
A: FU901BC can be mounted on suitable transparent or translucent pipes, including glass and PFA tubing, provided the wall thickness and optical properties meet the detection requirements.


Q4: How does FU901BC detect liquid levels?
A: It monitors changes in light refraction between empty and liquid-filled pipe sections. A compatible fiber amplifier processes the received light signal to determine whether liquid is present at the sensing position.


Q5: Does FU901BC need to contact the liquid?
A: No. FU901BC mounts externally and detects liquid through the pipe wall, without inserting the sensing head into the liquid.


Q6: Can FU901BC detect every type of liquid?
A: Not necessarily. It is intended for liquid level detection in transparent or translucent pipes, but some liquids, including certain milky-white liquids, may not be detectable. Actual compatibility should be verified.


Q7: What is the repeatability of FU901BC?
A: FU901BC has a repeatability of 1 mm or less. It is intended for point-level detection rather than continuous measurement of liquid height.


Q8: Can FU901BC monitor both upper and lower liquid levels?
A: Yes. Two FU901BC units can be installed at different heights to monitor upper and lower level limits. When mounted separately with zip ties, the minimum spacing is 15 mm.


Q9: What are the fiber length and allowable bending radius?
A: FU901BC features a 2 m free-cutting fiber with an R10 (10 mm) allowable bending radius for equipment cable routing.


Q10: Which fiber amplifiers are compatible with FU901BC?
A: FU901BC supports F2R, F70R, F70AR, F71R, F80R, and F85RN fiber amplifiers. Select the amplifier based on the required control features and settings.