FAQ
Q1: What is TAKEX FUH612BC?
A: FUH612BC is a 130°C heat-resistant U-shaped through-beam fiber optic unit with a fixed 12 mm sensing gap for non-contact industrial object detection.
Q2: What is the maximum operating temperature of FUH612BC?
A: FUH612BC has an ambient operating temperature range of −30 to +130°C. Actual installation and fiber routing conditions should be checked before use.
Q3: What is the fixed sensing gap of FUH612BC?
A: FUH612BC has a fixed 12 mm sensing gap determined by the integrated transmitter and receiver positions. The gap cannot be changed through amplifier settings.
Q4: Why does FUH612BC not require optical-axis adjustment?
A: The transmitter and receiver positions are integrated into the same U-shaped sensing head, eliminating the need for separate emitter and receiver alignment.
Q5: What are the sensing head dimensions of FUH612BC?
A: The sensing head measures 30 × 24 × 5 mm, is made of black-anodized aluminum, and includes two φ3.2 mm mounting holes.
Q6: What materials are used in the FUH612BC fiber?
A: The fiber has a fluoroplastic covering and a thermosetting acrylic core. Its cable diameter is φ2.2 mm, and its core diameter is φ1.5 mm.
Q7: How long is the FUH612BC fiber, and can it be cut?
A: FUH612BC features a 2 m free-cutting fiber cable that can be trimmed to meet installation requirements.
Q8: What is the allowable bending radius of FUH612BC?
A: The fiber has an R45 (45 mm) allowable bending radius, which must be maintained during cable routing.
Q9: Which fiber amplifiers are compatible with FUH612BC?
A: FUH612BC supports F100R, F2R, F70, F80R, F85RN, and XF12R-A fiber amplifiers. Select the amplifier according to the required control functions.
Q10: How does FUH612BC differ from FU1001BC, FU1002BC, and FU1004BC?
A: FUH612BC is rated for 130°C heat resistance, has a fixed 12 mm sensing gap, and uses a fluoroplastic-covered fiber with an R45 bending radius. The FU1001BC, FU1002BC, and FU1004BC models are rated for 115°C, have fixed 5 mm gaps, and feature heat-resistant polyethylene coverings with R15 bending radii.