FAQ
Q1: What is TAKEX FXN84BC?
A: FXN84BC is an M4 threaded narrow-view coaxial reflective fiber optic unit featuring one transmitting fiber and nine receiving fibers for non-contact object detection.
Q2: What is the main feature of the FXN84BC narrow-view design?
A: Its narrower sensing field is intended for short-range reflective detection within a more focused area. Actual performance depends on target and surrounding conditions.
Q3: What does a 1-transmit/9-receive coaxial configuration mean?
A: One central transmitting fiber is surrounded by nine receiving fibers that collect light reflected from the target. The nine receiving fibers do not provide nine independent outputs.
Q4: What is the maximum reference detecting distance of FXN84BC?
A: FXN84BC provides a 50 mm reference detecting distance with F85RN in long-distance mode. Actual performance varies with target reflectivity and amplifier settings.
Q5: What are the detecting distances with F80R?
A: With F80R, FXN84BC provides 40 mm in long-distance mode and 22 mm in high-speed mode.
Q6: What are the detecting distances with F70R, F71R, and F2R?
A: The detecting distances are 22 mm with F70R/F70AR, 13 mm with F71R, and 5 mm with F2R.
Q7: What thread size does FXN84BC use?
A: FXN84BC features an M4 × P0.7 threaded head with a φ2.5 mm sensing tip and SUS303 stainless steel construction. Maximum tightening torque is 0.8 N·m.
Q8: Can the FXN84BC fiber cable be cut to length?
A: Yes. FXN84BC includes a 2 m free-cutting fiber cable that can be trimmed to meet equipment installation requirements.
Q9: Does the narrow-view design provide a fixed minute spot diameter?
A: No fixed spot diameter is specified for FXN84BC. The model is characterized by its narrow-view coaxial reflective design, and the sensing area must be evaluated for the actual operating distance.
Q10: What is the difference between FXN84BC and FX8404BC?
A: Both models feature M4 threads and a 1-transmit/9-receive coaxial design. FXN84BC is a narrow-view model for short-range sensing, while FX8404BC is a general coaxial reflective model. Select based on the required sensing field and operating distance.