FAQ
Q1: Does the FZ1901YBC need a separate fiber amplifier?
A: Yes. The head transmits and receives light. The amplifier evaluates the change in received light and provides the switching output. Compatible models include the F70R, F80R, and F85RN.
Q2: What does R1 mean for cable routing?
A: R1 specifies a 1 mm min. bend radius. Each fiber cable has an outer diameter of Ø2.2 mm, so check both the available channel width and the radius at each turn.
Q3: What target is used for the 50 mm detecting distance?
A: The rating is 50 mm with an F70R amplifier and a 50 × 50 mm sheet of white drawing paper. Verify the working distance with a sample if your target has a different surface or moves closer to or farther from the head.
Q4: How can I check whether the head fits an existing bracket?
A: The head measures 20 × 20 × 8 mm and has two Ø3.4 mm mounting holes on 7 mm centers. The center of the hole nearest the cable exit is 4 mm from that edge. Use these dimensions to check hole alignment and orientation.
Q5: Which F85RN mode should I use for fast-moving parts?
A: Start with high-speed mode (H-SP). Both high-speed and long-distance modes are rated for 50 mm with the FZ1901YBC. F85RN response time is 65 μs max. in high-speed mode and 4 ms max. in long-distance mode. Compare these times with how long the part is in the sensing zone.
Q6: Can I shorten the 2 m fiber cables?
A: Yes. Both cables can be cut at the amplifier end. Mount the head first and measure along the actual cable route to the amplifier before trimming.
Q7: Which temperature rating applies if the head and amplifier are installed separately?
A: The FZ1901YBC fiber optic unit is rated for −30 to +70 °C. If the amplifier is inside a control cabinet, check the temperature inside the cabinet against that amplifier's own rating.
Q8: What is the smallest detectable object, and does the rating apply to an F71R?
A: The rated object diameter is Ø0.015 mm, except with the F71R. For an existing F71R installation, use 50 mm as the rated detecting distance and test the response with a sample of the small part.
Q9: Can I keep the same setting when switching from a white part to a black one?
A: Recheck the setting after a color change. With the F80R, white and black drawing paper produce different received-light curves as distance changes. Compare the readings with the actual part present and absent at the working position before adjusting the threshold.
Q10: How do I choose between the FZ1901YBC and FZV191YBC?
A: Both allow a 1 mm bend radius. With the F70R, the FZ1901YBC is rated for 50 mm using white drawing paper. For clear glass at 0–6 mm, consider the FZV191YBC, which has a 4 mm thick head and uses a clear glass plate as its standard target.