FAQ
Q1: Can I use the FZV191YBC if I only have access to one side of the glass?
A: Yes. The same head transmits light and receives the reflection from the glass. A separate fiber amplifier converts the change in received light into a switching signal for glass presence or absence.
Q2: How much space should I leave between the head and the glass?
A: With the F70R or F80R, the detecting range for a transparent glass plate is 0–6 mm, measured from the sensing window to the glass surface. Allow for the full variation in glass height as it passes the head.
Q3: Why does the amplifier still indicate glass after the sheet is removed?
A: Excess sensitivity can cause a false reading. Remove the glass, hold the F80R teaching button for 3 seconds, and release it when SEt appears. Place the glass in its working position, press again, and release at SEt. Remove and reinsert the glass to verify both switching states.
Q4: Does the glass substrate have to be 0.7 mm thick?
A: The 0.7 mm thickness describes the sample used for the typical F80R response curve. For a different thickness, test the actual glass at the intended distance and compare the readings with the sample present and absent.
Q5: Will long-distance mode let me move the head more than 6 mm away?
A: With the F80R or F85RN, both long-distance and high-speed modes are rated for 0–6 mm. For fast-moving parts, compare amplifier response times. The F80R is rated at 190 μs max. in high-speed mode and 1.8 ms max. in long-distance mode.
Q6: What mounting hole pattern and screw torque should I allow for?
A: The head has two Ø3.2 mm holes on 7 mm centers, with Ø6.1 mm recesses on both faces. Check screw head clearance against your bracket and tighten the mounting screws to 0.8 N·m max.
Q7: How do R1 and the 1.0 mm cable diameter affect routing?
A: R1 specifies the 1 mm min. bend radius at each turn. The 1.0 mm outer diameter of each cable determines channel clearance and adapter size. The multicore fiber inside has a diameter of 0.75 mm.
Q8: Can I shorten the 2 m cables before connecting them to an F70R?
A: Yes. Measure the cable route from the fixture to the amplifier, then trim the amplifier ends. With the F70R, use the gray FA191BC fiber adapter for the 1.0 mm outer cable diameter.
Q9: What should I measure before requesting a quote?
A: Provide the glass thickness, the nearest and farthest window-to-glass distances, and the available mounting height. For an existing installation, include the amplifier model and required cable length so the fiber and amplifier can be checked together.
Q10: How do I choose between the FZV191YBC and FZ1901YBC?
A: With the F70R, the FZV191YBC is rated for 0–6 mm on clear glass and has a 4 mm thick head. The FZ1901YBC is rated for 50 mm on 50 × 50 mm white drawing paper and has an 8 mm thick head. Choose for your target material and the clearance in your fixture.