FAQ
Q1: How do these units detect a part from one side?
A: The head transmits and receives light through the same side-facing window. When a part enters the area where the two optical paths overlap, reflected light travels back through the fiber to the amplifier, which provides the output signal.
Q2: What are the main differences between FZV8202BC and FZV8203BC?
A: With an F70R and the standard clear glass target, the FZV8202BC covers 0–5 mm and allows a cable bend radius as small as 15 mm. The FZV8203BC covers 0–19 mm and needs at least a 30 mm bend radius.
Q3: What are the test conditions for clear glass detection?
A: The standard target is a 50 × 50 mm clear glass plate used with an F70R fiber amplifier. If your glass has a different size or surface finish, check detection with a sample at the intended mounting position.
Q4: Does switching the F80R from high-speed to long-distance mode extend the range?
A: Both F80R modes have the same specified range for these units. It is 0–5 mm for the FZV8202BC and 0–19 mm for the FZV8203BC.
Q5: Can I reuse the mounting holes when switching models?
A: Yes. Both heads measure 18 × 10 × 2 mm and have two M3 threaded through holes on 7 mm centers. When changing models, also check the window-to-target distance and the space available for cable bends.
Q6: What do Ø0.06 mm and Ø0.015 mm specify?
A: They specify the min. detectable object diameter. The values are Ø0.06 mm for the FZV8202BC and Ø0.015 mm for the FZV8203BC, and both exclude the F71R. To evaluate a specific glass thickness, test a sample of that glass.
Q7: Can I shorten the 2 m fibers to fit my machine?
A: Yes. Both models have cut-to-length fibers. Lay out the path from the head to the amplifier, allow for the required bend radius, and trim the fibers at the amplifier end.
Q8: What temperature range applies near a heat source?
A: The ambient temperature range for both fiber optic units is −30 to +70 °C. Check the temperature along the cable and at the sensing head. Use the amplifier's own temperature rating when choosing its mounting location.
Q9: Which combination can detect a semiconductor lead frame from below?
A: Pair the FZV8202BC with an F85RN fiber amplifier. Place the 2 mm head below the lead frame with the side window facing the part. Set the switching point using a production lead frame.
Q10: What if the glass is 12 mm from the window but the cable route only allows a 20 mm bend radius?
A: With an F70R and the standard glass target, 12 mm falls within the FZV8203BC range. Reroute the fiber to allow at least a 30 mm radius. If the 20 mm bend radius is fixed, move the head to within 5 mm of the glass and use the FZV8202BC.