FAQ
Q1: Is the FZV8301BC a fiber optic unit or a sensor with a built-in amplifier?
A: It is a convergent reflective fiber optic unit consisting of a sensing head and fibers. A separate fiber amplifier processes the received light and provides the detection output.
Q2: Where can I mount the head to detect a substrate on a robot?
A: Recess the 3 mm head into the end effector with its window facing the substrate. The head sends and receives light from one side, leaving the other side accessible to the handling mechanism.
Q3: What dimensions do I need to design the mounting bracket?
A: The head measures 18 × 10 × 3 mm and has two M3 through holes on 7 mm centers. Keep the sensing window clear and leave room for the fibers to exit the back of the head.
Q4: What target gives the 0–20 mm range with an F70R amplifier?
A: The FZV8301BC has a 0–20 mm detecting distance with an F70R and a 50 × 50 mm clear glass reference plate. Use a production substrate to confirm the working gap for your application.
Q5: Does the range change between high-speed and long-distance modes on the F80R?
A: Both F80R modes specify 0–20 mm with the FZV8301BC. A working gap greater than 20 mm exceeds the specified range for this combination.
Q6: How should I set the amplifier sensitivity during setup?
A: Use reduced sensitivity with the F70R, F70AR, F80R, F85RN, or F100R. Place and remove a substrate at the actual handling position and check that the output switches between the two states.
Q7: Can I shorten the 2 m fiber, and how much space do bends need?
A: Yes. Plan the route with a bend radius of at least 20 mm, then trim the fiber at the amplifier end. R20 refers to the radius of the bend.
Q8: What does the Ø0.015 mm specification mean?
A: It is the min. detectable object diameter and excludes the F71R amplifier. To determine whether a particular glass thickness can be detected, test a sample of that glass.
Q9: What ambient temperature can the fiber unit handle near a heat source?
A: The FZV8301BC is rated for −30 to +70 °C. Check the ambient temperature at the head and along the fiber route, and select the amplifier location using its own temperature rating.
Q10: How do I choose between the FZV8301BC and the FZV8203BC in a tight space?
A: Choose the FZV8203BC if the recess only takes a 2 mm head and the fiber can follow a 30 mm bend radius. If a 3 mm head fits but the route allows only a 20 mm radius, choose the FZV8301BC. With an F70R and a 50 × 50 mm clear glass plate, the ranges are 0–19 mm for the FZV8203BC and 0–20 mm for the FZV8301BC.