TAKEX_GLT505J

200°C-Rated Through-Beam Fiber Optic Units with Fluoropolymer Tubing

  • TAKEX GLT505J, GLT510J, and GLT520J through-beam units use M4 tips rated from −60 to +200°C. The 0.5, 1, and 2 m glass fiber cables have 200°C PFA tubing and a 25 mm min. bend radius. An F80R detects passing parts across gaps up to 610 mm in long-distance mode or 340 mm in high-speed mode.
  • Brand TAKEX Takenaka Engineering Co., Ltd.
Features
  • Part detection by beam interruption: Mount the emitter and receiver opposite each other. A part passing between them interrupts the beam, allowing the amplifier to detect its presence.
  • 200°C heat resistance: PFA tubing protects the glass fibers, and the sensing tips operate from −60 to +200°C. Mount the amplifier where the ambient temperature meets its own operating limits.
  • Three cable lengths: The GLT505J has a 0.5 m cable, the GLT510J has a 1 m cable, and the GLT520J has a 2 m cable. Size the cable for the longer of the two routes to the amplifier.
  • Two F80R sensing ranges: All three units reach 610 mm in long-distance mode and 340 mm in high-speed mode.
  • M4 threaded mounting: The SUS303 stainless steel tips have M4 × 0.7 threads rated for a tightening torque of 0.8 N·m max. Allow a bend radius of at least 25 mm when routing the fiber.
Specification
ItemSpec.
ModelsGLT505J
GLT510J
GLT520J
Detection methodThrough-beam
Fiber cable length L (m)GLT505J: 0.5
GLT510J: 1
GLT520J: 2
Sensing head thread size (mm)M4 × 0.7
Threaded head materialSUS303 stainless steel
Thread tightening torque, max. (N·m)0.8
Ambient temperature at the sensing tip (°C)−60 to +200
Tubing temperature rating (°C)200
Tubing / fiber materialPFA / glass
Cable outside diameter (mm)2.8
Glass fiber bundle diameter (mm)1.0
Allowable bend radius, min. (mm)25
F80R detecting distance, long-distance mode (mm)610
F80R detecting distance, high-speed mode (mm)340
F70R / F70AR detecting distance (mm)340
F71R detecting distance (mm)195
XF12R-A detecting distance, Long mode (mm)460
XF12R-A detecting distance, H-SP mode (mm)190
Standard detectable object diameter (mm)1
Detectable object diameter, min. (mm, excluding F71R and F2R)0.015
Additional compatible fiber amplifierF85RN

Specification notes

  • Cable length L is the section between the end fittings in the dimension drawing. Allow extra space for the fittings and cable bends.
  • Detecting distance is the optical gap between the emitter and receiver. If the installation uses both F80R modes, choose a gap within the rating for each mode.
  • When detecting an object as small as 0.015 mm in diameter, check the amplifier model and test an actual part at the planned sensing gap.
FAQ

Q1: How do these fiber optic units detect a part?
A: The emitter and receiver face each other. The amplifier sends light through the transmitting fiber and monitors light returning through the receiving fiber. A part crossing the beam changes the amount of light received.


Q2: How do the GLT505J, GLT510J, and GLT520J differ?
A: Cable length is the main difference. The GLT505J is 0.5 m, the GLT510J is 1 m, and the GLT520J is 2 m. All three have the same mounting threads, tip temperature range, and F80R sensing ranges.


Q3: Which parts carry the 200°C rating?
A: The sensing tips are rated for ambient temperatures from −60 to +200°C. The PFA tubing is rated to 200°C. Install the amplifier within its own ambient temperature range.


Q4: Which F80R mode should I use for a 500 mm sensing gap?
A: Use long-distance mode, which is rated to 610 mm. High-speed mode is rated to 340 mm, so it cannot cover a 500 mm gap.


Q5: What sensing gap can I use with an F70R, F70AR, or F71R?
A: The F70R and F70AR are each rated for 340 mm with these units. The F71R is rated for 195 mm. When replacing a fiber unit, check the installed amplifier model and measure the gap between the heads.


Q6: How do I mount the M4 sensing heads?
A: Use a mount that accepts M4 × 0.7 threads and align the emitter with the receiver. Limit tightening torque on the threads to 0.8 N·m.


Q7: How do I select a cable length if the amplifier is already installed?
A: Measure each head’s cable route to the amplifier, including bends. Choose 0.5, 1, or 2 m to cover the longer route. Keep the fittings at both ends intact during installation.


Q8: How tightly can I bend the 2.8 mm cable?
A: Allow a bend radius of at least 25 mm. Leave room for a gradual curve around fixture corners and avoid a sharp bend where the cable exits a fitting.


Q9: Can these units detect a part as small as 0.015 mm in diameter?
A: All three have a min. detectable object diameter of 0.015 mm. This rating excludes the F71R and F2R. If the part blocks only a portion of the beam, test it at the intended gap and check the change in received light.


Q10: What if I only have mounting access on one side of the part?
A: These through-beam units need an emitter and a receiver on opposite sides of the sensing path. For one-sided access, consider the heat-resistant GLX505J, GLX510J, or GLX520J reflective unit. Select it for the target surface and working distance.