Close
Search
Banner Banner
Products
請選擇分類
TAKEX_GTH505J

350°C Through-Beam Fiber Optic Units with Stainless Steel Spiral Tubing

  • TAKEX GTH505J, GTH510J, and GTH520J are 350°C-rated through-beam glass fiber units with stainless steel spiral tubing. Lengths are 0.5, 1, and 2 m. All reach 610 mm in F80R long-distance mode or 340 mm in high-speed mode. The FA514 lens for detecting glass plates at a furnace exit is rated to 200°C.
  • Brand TAKEX Takenaka Engineering Co., Ltd.
Features
  • Separate emitter and receiver heads: The two M4 threaded heads face each other across the sensing area. The amplifier detects a change in received light when an object passes through the beam.
  • 350°C heat resistance: Stainless steel spiral tubing covers the glass fibers. The fiber unit is rated for ambient temperatures from −60 to +350°C.
  • Three cable lengths: The GTH505J has a 0.5 m cable, the GTH510J has a 1 m cable, and the GTH520J has a 2 m cable. All have a 2.8 mm cable diameter and a min. bend radius of 25 mm.
  • Two F80R sensing ranges: All three units reach 610 mm in F80R long-distance mode and 340 mm in high-speed mode.
  • Glass plate detection at a furnace exit: The FA514 lens fits the M4 threaded head to extend the sensing distance across the glass plate conveyor. The lens is rated to 200°C.
Specification
ItemSpec.
ModelsGTH505J
GTH510J
GTH520J
Detection methodThrough-beam
Fiber cable length L (m)GTH505J: 0.5
GTH510J: 1
GTH520J: 2
Fiber unit ambient temperature (°C)−60 to +350
Cable coveringStainless steel spiral tubing
Fiber materialGlass
Cable outside diameter (mm)2.8
Glass fiber bundle diameter (mm)1.0
Allowable bend radius, min. (mm)25
Sensing head thread size (mm)M4 × 0.7
Thread tightening torque, max. (N·m)0.8
F80R detecting distance, long-distance mode (mm)610
F80R detecting distance, high-speed mode (mm)340
F70R / F70AR detecting distance (mm)340
F71R detecting distance (mm)195
F85RN detecting distance, long-distance mode (mm)GTH505J: -
GTH510J: 1,070
GTH520J: 1,070
F85RN detecting distance, high-speed mode (mm)GTH505J: -
GTH510J: 290
GTH520J: 290
XF12R-A detecting distance, Long mode (mm)460
XF12R-A detecting distance, H-SP mode (mm)190
Standard detectable object diameter (mm)1
Detectable object diameter, min. (mm, excluding F71R and F2R)0.015
Compatible lens unitFA514

Specification notes

  • Dimension L is the length of fiber cable between the back of the sensing head and the amplifier-end fitting. Detecting distance is the gap between the emitter and receiver heads.
  • All three units are compatible with the F85RN. A dash indicates that only compatibility is listed for that combination. The 1,070 mm rating for the GTH510J and GTH520J applies to F85RN long-distance mode.
  • The distances in the table apply to the fiber units paired with the listed amplifiers. Adding the FA514 changes the optical setup. The temperature at the lens must stay within its 200°C rating.
FAQ

Q1: How do the GTH505J, GTH510J, and GTH520J detect an object?
A: All three use through-beam sensing. The emitter and receiver face each other on opposite sides of the sensing area. The amplifier sends and receives light through the glass fibers and detects the change as an object crosses the beam.


Q2: How do I choose between the 0.5, 1, and 2 m cable lengths?
A: Choose a length that covers the cable route from each head to the amplifier. The GTH505J is 0.5 m, the GTH510J is 1 m, and the GTH520J is 2 m. All three have the same rated detecting distance with the F80R.


Q3: Will the F80R still cover a 610 mm gap in high-speed mode?
A: The 610 mm rating applies to long-distance mode. In high-speed mode, all three units are rated for 340 mm.


Q4: What sensing distance can I use with an F70R, F70AR, or F71R?
A: All three fiber units are rated for 340 mm with the F70R or F70AR and 195 mm with the F71R.


Q5: Can I use an F85RN or XF12R-A amplifier?
A: Both amplifiers are compatible with all three fiber units. With the F85RN, the GTH510J and GTH520J reach 1,070 mm in long-distance mode and 290 mm in high-speed mode. With the XF12R-A, all three reach 460 mm in Long mode and 190 mm in H-SP mode.


Q6: What bend radius does the cable require?
A: Allow a bend radius of at least 25 mm. The cable is 2.8 mm in diameter over the spiral tubing, and the glass fiber bundle is 1.0 mm in diameter.


Q7: What thread size and torque limit apply to the sensing head?
A: The heads have M4 × 0.7 threads rated for a tightening torque of 0.8 N·m max. The hex nut measures 7 mm across the flats and is 2.4 mm thick.


Q8: What are the standard and smallest detectable object diameters?
A: The standard detectable object diameter is 1 mm. The min. detectable object diameter is 0.015 mm. The 0.015 mm rating excludes the F71R and F2R.


Q9: How are the heads arranged to detect glass plates leaving a furnace?
A: The emitter and receiver face each other above and below the conveyor. The FA514 lens extends the sensing distance, and the glass plate passes through the beam as it leaves the furnace.


Q10: Can the FA514 lens operate at the fiber unit’s 350°C rating?
A: The FA514 lens is rated to 200°C. The −60 to +350°C ambient range applies to the GTH fiber unit. Check the temperature at each component's mounting location when laying out the furnace-exit installation.

0