FAQ
Q1: How do the GTH505J, GTH510J, and GTH520J detect an object?
A: All three use through-beam sensing. The emitter and receiver face each other on opposite sides of the sensing area. The amplifier sends and receives light through the glass fibers and detects the change as an object crosses the beam.
Q2: How do I choose between the 0.5, 1, and 2 m cable lengths?
A: Choose a length that covers the cable route from each head to the amplifier. The GTH505J is 0.5 m, the GTH510J is 1 m, and the GTH520J is 2 m. All three have the same rated detecting distance with the F80R.
Q3: Will the F80R still cover a 610 mm gap in high-speed mode?
A: The 610 mm rating applies to long-distance mode. In high-speed mode, all three units are rated for 340 mm.
Q4: What sensing distance can I use with an F70R, F70AR, or F71R?
A: All three fiber units are rated for 340 mm with the F70R or F70AR and 195 mm with the F71R.
Q5: Can I use an F85RN or XF12R-A amplifier?
A: Both amplifiers are compatible with all three fiber units. With the F85RN, the GTH510J and GTH520J reach 1,070 mm in long-distance mode and 290 mm in high-speed mode. With the XF12R-A, all three reach 460 mm in Long mode and 190 mm in H-SP mode.
Q6: What bend radius does the cable require?
A: Allow a bend radius of at least 25 mm. The cable is 2.8 mm in diameter over the spiral tubing, and the glass fiber bundle is 1.0 mm in diameter.
Q7: What thread size and torque limit apply to the sensing head?
A: The heads have M4 × 0.7 threads rated for a tightening torque of 0.8 N·m max. The hex nut measures 7 mm across the flats and is 2.4 mm thick.
Q8: What are the standard and smallest detectable object diameters?
A: The standard detectable object diameter is 1 mm. The min. detectable object diameter is 0.015 mm. The 0.015 mm rating excludes the F71R and F2R.
Q9: How are the heads arranged to detect glass plates leaving a furnace?
A: The emitter and receiver face each other above and below the conveyor. The FA514 lens extends the sensing distance, and the glass plate passes through the beam as it leaves the furnace.
Q10: Can the FA514 lens operate at the fiber unit’s 350°C rating?
A: The FA514 lens is rated to 200°C. The −60 to +350°C ambient range applies to the GTH fiber unit. Check the temperature at each component's mounting location when laying out the furnace-exit installation.