FAQ
Q1: How do the GTH510FEJ and GTH540FEJ detect an object?
A: Both are through-beam fiber optic units used with a fiber amplifier. The transmitting head sends light to the opposing receiving head. When an object interrupts the beam, the amplifier detects the change in received light.
Q2: How do I choose between the GTH510FEJ and GTH540FEJ?
A: Measure the cable route from the sensing head to the amplifier. Choose the GTH510FEJ for a 1 m cable or the GTH540FEJ for a 4 m cable. If you already have an amplifier, check the detecting distance for its model and mode.
Q3: Which combination supports an 8 m gap between heads?
A: Use the GTH540FEJ with an F85RN amplifier in long-distance mode. The 8,000 mm rating is the distance between the heads. The GTH540FEJ fiber cable is 4 m long.
Q4: How far can each model detect in F85RN high-speed mode?
A: The GTH510FEJ reaches 2,000 mm and the GTH540FEJ reaches 2,750 mm. Use these distances to check head spacing if the application requires high-speed mode.
Q5: Can I use an existing F80R, F70R, or F70AR amplifier?
A: Yes. With the F80R, both fiber units reach 1,800 mm in long-distance mode and 1,000 mm in high-speed mode. With the F70R or F70AR, both reach 1,000 mm.
Q6: How far does the PFA tubing extend along the cable?
A: The PFA tube runs along the cable from the sensing end and stops before the amplifier connection. The dimensional drawing shows exposed stainless steel spiral tubing between the end of the PFA tube and the connector.
Q7: Which diameter should I use for mounting or routing?
A: The sensing head is 9 mm in diameter, the PFA tube has a 6.35 mm outer diameter, and the fiber cable inside is 2.8 mm in diameter. Use the dimension of the part that will be mounted or routed through an opening.
Q8: What bend radius do the fiber cables require?
A: Both units are rated R50. Keep the bend radius at 50 mm or more with either the 1 m or the 4 m cable.
Q9: What does the 6 mm target specification mean?
A: It is the standard target diameter for both fiber units. If you need to detect a smaller workpiece, verify detection with a sample of that size.
Q10: Can the amplifier be installed with the fiber unit at 200°C?
A: The fiber unit is rated for 200°C max. Install the amplifier within its own ambient temperature range. For example, a single F85RN amplifier is rated for −25 to +55 °C.