Close
Search
Banner Banner
Products
請選擇分類
TAKEX_GXH505J

350°C Reflective Fiber Units with Stainless Steel Spiral Tubing

  • TAKEX GXH505J (0.5 m), GXH510J (1 m), and GXH520J (2 m) are M4 reflective fiber optic units rated for −60 to +350 °C. Each has a single-sided sensing head, glass fiber in stainless steel spiral tubing, and a dedicated amplifier connector. With the F71R, they reach 45, 45, and 40 mm, respectively.
  • Brand TAKEX Takenaka Engineering Co., Ltd.
Features
  • Single-sided detection: The same head directs light at the target and receives the reflected light. Only one side of the target needs mounting space for the head.
  • 350°C heat resistance: The fiber units use glass fiber protected by stainless steel spiral tubing and are rated for −60 to +350 °C. Mount the amplifier within its own ambient temperature range.
  • Three cable lengths with dedicated connectors: Choose the GXH505J for 0.5 m, the GXH510J for 1 m, or the GXH520J for 2 m. Each cable has a dedicated connector at the amplifier end.
  • F80R long-distance and high-speed modes: With the F80R, the GXH505J reaches 135 mm in long-distance mode and 75 mm in high-speed mode. The GXH520J reaches 130 mm and 70 mm in the same two modes.
  • M4 mounting and cable routing: The head has an M4 × 0.7 thread with a tightening torque of 0.8 N·m max. Allow a bend radius of at least 25 mm for the 2.8 mm diameter cable.
Specification
ItemSpec.
ModelsGXH505J
GXH510J
GXH520J
Detection methodReflective
Fiber cable length L (m)GXH505J: 0.5
GXH510J: 1
GXH520J: 2
Fiber unit ambient temperature (°C)−60 to +350
Sensing head thread size (mm)M4 × 0.7
Thread tightening torque, max. (N·m)0.8
Sensing face to start of spiral tubing (mm)23
Outer protective tubingStainless steel spiral tubing
Fiber core materialGlass
Fiber cable outer diameter (mm)2.8
Fiber bundle diameter (mm) and configuration1.1, two sections
Allowable bend radius, min. (mm)25
Amplifier connectionDedicated connector
Standard target with F70R100 × 100 mm white drawing paper
Detectable target diameter, min. (mm, excluding F71R)0.015
F80R detecting distance, long-distance mode (mm)GXH505J: 135
GXH510J: -
GXH520J: 130
F80R detecting distance, high-speed mode (mm)GXH505J: 75
GXH510J: -
GXH520J: 70
F70R / F70AR detecting distance (mm)GXH505J: 75
GXH510J: -
GXH520J: 70
F71R detecting distance (mm)GXH505J: 45
GXH510J: 45
GXH520J: 40
F85RN detecting distance, high-speed mode (mm)GXH505J: -
GXH510J: 80
GXH520J: 80
XF12R-A detecting distance, long-distance mode (mm)130
XF12R-A detecting distance, H-SP mode (mm)45

Specification notes

  • Use cable length L to plan the route to the amplifier. For head-to-target spacing, use the distance for the selected amplifier and mode. All three fiber units work with the listed amplifiers. A dash means no distance is listed here for that combination.
  • The standard target with the F70R is 100 × 100 mm white drawing paper. For a 0.015 mm diameter target, verify detection with the actual part at the intended working distance.
  • Allow room for the mounting hardware as well as the M4 thread. The hex nut measures 7 mm across flats, and the internal-tooth lock washer has an 8.5 mm outer diameter.
FAQ

Q1: Can I use these units if I can mount a head on only one side of the target?
A: Yes. The GXH505J, GXH510J, and GXH520J transmit and receive light through the same head. The fiber amplifier detects a change in the light reflected by the target.


Q2: Which model should I choose for my cable run?
A: Measure the route from the sensing head to the amplifier. Choose the GXH505J for 0.5 m, the GXH510J for 1 m, or the GXH520J for 2 m. All three have a dedicated connector at the amplifier end.


Q3: Does the 350°C rating also apply to the fiber amplifier?
A: The −60 to +350 °C rating applies to the fiber unit. Choose an amplifier location within that amplifier’s own temperature range. For example, a single F85RN is rated for −25 to +55 °C.


Q4: What thread pitch and tightening torque should I use?
A: All three heads have an M4 × 0.7 thread with a 0.7 mm pitch. Tighten to 0.8 N·m max. The sensing face is 23 mm from the start of the spiral tubing.


Q5: How far do the 0.5 m and 2 m models reach with an F80R?
A: The 0.5 m GXH505J reaches 135 mm in long-distance mode and 75 mm in high-speed mode. The 2 m GXH520J reaches 130 mm in long-distance mode and 70 mm in high-speed mode.


Q6: If I keep my F71R and switch to a 2 m cable, will I need to move the head?
A: The GXH505J and GXH510J each reach 45 mm with the F71R. The 2 m GXH520J reaches 40 mm. If your current head is mounted 45 mm from the target, move it closer when fitting the GXH520J.


Q7: Which distance should I use when setting up an XF12R-A?
A: All three units reach 130 mm in long-distance mode and 45 mm in H-SP mode. If the amplifier will run in H-SP mode, use 45 mm when planning the head-to-target spacing.


Q8: What does R25 mean for cable routing?
A: R25 specifies a bend radius of at least 25 mm. All three cables have a 2.8 mm outer diameter and require the same bend radius, including the longer versions.


Q9: What do the 1.1 mm and 0.015 mm diameters refer to?
A: The entire glass fiber bundle is 1.1 mm in diameter and is divided into two sections. The 0.015 mm value is the min. detectable target diameter. This target rating excludes the F71R.


Q10: What target should I use as a reference with the F70R?
A: The standard target is 100 × 100 mm white drawing paper. If your target differs in size or surface finish, check the reflected signal with your actual part at the intended working distance.

0