FAQ
Q1: Where are the GTH705V and GTH710V installed in a vacuum system?
A: Both models are installed inside the chamber. The fiber runs from the sensing point to the feedthrough pin in the chamber wall. An air-side fiber completes the connection to the amplifier.
Q2: How do I choose between the GTH705V and GTH710V?
A: Follow the planned cable route from the pin to the sensing head. Choose the GTH705V for a 0.5 m route or the GTH710V when you need 1 m. Both use the same M4 mounting thread and have the same sensing range with each listed amplifier and mode.
Q3: What vacuum level are these fiber units rated for?
A: Both are rated for vacuum environments down to 1 × 10⁻⁸ Pa. This rating describes the pressure at which the fiber unit can be used. The feedthrough pin has a separate leak rate specification.
Q4: Which threads are used at the sensing head and the feedthrough end?
A: The sensing head has a 20 mm long M4 × 0.7 mm thread. At the opposite end, an M5 locking ring with an 8 mm outer diameter secures the fiber to the feedthrough pin.
Q5: Which F100R mode provides a 950 mm through-beam range?
A: Select long-distance mode for 950 mm with either fiber unit. Switching the F100R to high-speed mode gives a range of 380 mm.
Q6: What range can I expect with an existing F85RN or F80R amplifier?
A: With either fiber, the F85RN provides 680 mm in long-distance mode and 160 mm in H-SP mode. The F80R provides 500 mm in long-distance mode.
Q7: Which part of the fiber unit is rated to 350°C?
A: The 350°C rating applies to the L2 section at the sensing head. Route the L1 section, which includes the connection at the locking ring, through an area within its 200°C rating.
Q8: Which fiber in the system can be cut to length?
A: The FT7VBC-M5 is a 2 m air-side fiber that can be cut to length. For the route inside the chamber, select the 0.5 m GTH705V or the 1 m GTH710V.
Q9: Can I use the 1 mm copper wire specification at a 950 mm gap with the GTH705V?
A: Approximately 1 mm is the min. detectable copper wire diameter. The 950 mm figure is the through-beam range with an F100R in long-distance mode. For fine wire, verify detection at the actual wire diameter and mounting distance.
Q10: How are the fibers arranged to detect a wafer in a vacuum chamber?
A: Aim the transmitting and receiving heads at the same point on the wafer in a V configuration. This arrangement directs light reflected from the wafer into the receiving head and reduces the influence of background reflections.