Close
Search
Banner Banner
Products
請選擇分類
TAKEX_GTH705V

Pin-Coupled Vacuum Through-Beam Fiber Units

  • TAKEX GTH705V (0.5 m) and GTH710V (1 m) are through-beam fiber units for single-channel vacuum feedthrough pins. Both have M4 heads and a 1 × 10⁻⁸ Pa vacuum rating. The head section is rated to 350°C and the pin section to 200°C. Both reach 950 mm with an F100R in long-distance mode.
  • Brand TAKEX Takenaka Engineering Co., Ltd.
Features
  • Single-channel vacuum sensing: A feedthrough pin connects the vacuum-side fiber to the air-side fiber. Both models are rated for vacuum environments down to 1 × 10⁻⁸ Pa.
  • Two vacuum-side cable lengths: Choose the 0.5 m GTH705V or the 1 m GTH710V to suit the cable route inside the chamber. Both have an M4 × 0.7 mm threaded sensing head.
  • Temperature ratings by section: Stainless steel spiral tubing protects the fiber. The L2 section at the sensing head is rated to 350°C, and the L1 section at the feedthrough pin is rated to 200°C.
  • Range by amplifier mode: With an F100R fiber amplifier, either model reaches 950 mm in long-distance mode and 380 mm in high-speed mode.
  • Wafer detection in vacuum chambers: Aim the transmitting and receiving heads at the wafer in a V configuration. The resulting convergent reflection reduces the influence of background reflections.
Specification
ItemSpec.
ModelsGTH705V
GTH710V
Detection methodThrough-beam
ConnectionSingle-channel optical feedthrough pin
Vacuum-side fiber length L (m)GTH705V: 0.5
GTH710V: 1
Vacuum rating (Pa)1 × 10⁻⁸
Sensing head threadM4 × 0.7 mm
Threaded head length (mm)20
Fiber material and bundle diameterGTH705V: Glass, Φ1.5 mm
GTH710V: -
Protective tubingStainless steel spiral tube, Φ2.9 mm OD
Pin-side locking ringΦ8 mm OD, M5 thread
Ambient temperature, min. (°C)GTH705V: -30
GTH710V: -
Sensing head section L2, max. temperature (°C)350
Feedthrough pin section L1, max. temperature (°C)200
F100R detecting distance (mm)Long-distance 950, high-speed 380
F85RN detecting distance (mm)Long-distance 680, H-SP 160
F80R detecting distance (mm)Long-distance 500
F70R / F70AR detecting distance (mm)280
XF12R-A detecting distance (mm)Long-distance 280, H-SP 110
Detectable object, min. sizeGTH705V: Approx. Φ1 mm copper wire
GTH710V: -
Weight (g)GTH705V: 40 max.
GTH710V: -

Specification notes

  • Use fiber length L to plan the cable route inside the chamber. The through-beam detecting distances apply to the gap between the transmitting and receiving heads.
  • L2 extends from the M4 sensing head, and L1 extends from the feedthrough connection. Use the temperature rating for each section when routing the fiber through a heated area.
  • The GTH705V's approx. Φ1 mm value refers to copper wire. Detecting distance and min. detectable object size are separate specifications.
FAQ

Q1: Where are the GTH705V and GTH710V installed in a vacuum system?
A: Both models are installed inside the chamber. The fiber runs from the sensing point to the feedthrough pin in the chamber wall. An air-side fiber completes the connection to the amplifier.


Q2: How do I choose between the GTH705V and GTH710V?
A: Follow the planned cable route from the pin to the sensing head. Choose the GTH705V for a 0.5 m route or the GTH710V when you need 1 m. Both use the same M4 mounting thread and have the same sensing range with each listed amplifier and mode.


Q3: What vacuum level are these fiber units rated for?
A: Both are rated for vacuum environments down to 1 × 10⁻⁸ Pa. This rating describes the pressure at which the fiber unit can be used. The feedthrough pin has a separate leak rate specification.


Q4: Which threads are used at the sensing head and the feedthrough end?
A: The sensing head has a 20 mm long M4 × 0.7 mm thread. At the opposite end, an M5 locking ring with an 8 mm outer diameter secures the fiber to the feedthrough pin.


Q5: Which F100R mode provides a 950 mm through-beam range?
A: Select long-distance mode for 950 mm with either fiber unit. Switching the F100R to high-speed mode gives a range of 380 mm.


Q6: What range can I expect with an existing F85RN or F80R amplifier?
A: With either fiber, the F85RN provides 680 mm in long-distance mode and 160 mm in H-SP mode. The F80R provides 500 mm in long-distance mode.


Q7: Which part of the fiber unit is rated to 350°C?
A: The 350°C rating applies to the L2 section at the sensing head. Route the L1 section, which includes the connection at the locking ring, through an area within its 200°C rating.


Q8: Which fiber in the system can be cut to length?
A: The FT7VBC-M5 is a 2 m air-side fiber that can be cut to length. For the route inside the chamber, select the 0.5 m GTH705V or the 1 m GTH710V.


Q9: Can I use the 1 mm copper wire specification at a 950 mm gap with the GTH705V?
A: Approximately 1 mm is the min. detectable copper wire diameter. The 950 mm figure is the through-beam range with an F100R in long-distance mode. For fine wire, verify detection at the actual wire diameter and mounting distance.


Q10: How are the fibers arranged to detect a wafer in a vacuum chamber?
A: Aim the transmitting and receiving heads at the same point on the wafer in a V configuration. This arrangement directs light reflected from the wafer into the receiving head and reduces the influence of background reflections.

0