FAQ
Q1: Where do the GTSH705V and GTSH710V go in a vacuum system?
A: Both fiber units go inside the chamber. An FA7VP-M5 optical feedthrough pin connects the vacuum-side fiber to an air-side fiber, which runs to the amplifier outside the chamber.
Q2: How do I choose between the GTSH705V and GTSH710V?
A: Measure the route from the feedthrough pin to the sensing head and identify how much of it runs through the heated zone. The 0.5 m GTSH705V has a 400 mm section rated to 350°C. The 1 m GTSH710V provides 900 mm at that rating.
Q3: Can the fiber section next to the feedthrough pin withstand 350°C?
A: The 100 mm L1 section next to the feedthrough pin is rated to 200°C on both models. The 350°C rating applies to the L2 section at the sensing head.
Q4: Which dimensions should I check when designing the mounting fixture?
A: The M4 × 0.7 mm thread is 12 mm long. To locate the cable exit, allow for 29.5 mm from the sensing face to the cable centerline and 27 mm from the sensing head axis to the start of the spiral tubing.
Q5: What does R10 mean on the dimensional drawing?
A: R10 marks the 10 mm radius of the formed elbow. Use it to check clearance around the sensing head. The allowable cable bend radius is a separate routing specification.
Q6: Which amplifier and mode provide a 950 mm through-beam range?
A: Use an F100R fiber amplifier in long-distance mode with either fiber unit for 950 mm. Switching to high-speed mode gives a range of 380 mm.
Q7: With an F85RN, does the 1 m fiber increase the sensing range?
A: Both fibers provide 800 mm in long-distance mode and 200 mm in H-SP mode with the F85RN. The 1 m GTSH710V lets you route the cable to a sensing point farther from the feedthrough pin.
Q8: Which fiber in the system can be cut to length?
A: The FT7VBC-M5 is a 2 m air-side fiber that can be cut to length between the feedthrough pin and the amplifier. For the vacuum-side route, choose the 0.5 m GTSH705V or the 1 m GTSH710V.
Q9: How does the cable exit differ between the GTSH and GTH fiber units?
A: The GTSH705V and GTSH710V have right-angle heads that route the cable to the side. The GTH705V and GTH710V have straight heads with an axial cable exit. Choose the head that fits the space beside or behind the mounting fixture.
Q10: How are the GTSH fibers arranged to detect a wafer in a vacuum chamber?
A: Place the transmitting and receiving heads on the same side of the wafer. Aim them at the same point from different angles to form a V. The receiver collects light reflected from the wafer, reducing the influence of background reflections.