FAQ
Q1: Which side of the vacuum chamber do these units go on?
A: All four install on the vacuum side and connect at a flange. Mount the transmitting and receiving heads opposite each other so a part passing between them interrupts the beam.
Q2: How do the GTHN605V, GTHN610V, GTHN615V, and GTHN620V differ?
A: Their vacuum-side cable lengths are 0.5, 1, 1.5, and 2 m, respectively. They share the same head threads, but their detecting distances differ when paired with the F100R.
Q3: Where are the M4, M2.6, and M8 threads?
A: The sensing head has an M4 × 0.7 mm body thread and an M2.6 × 0.45 mm tip thread. The M8 thread is on the flange clamping ring at the other end of the cable.
Q4: Which model provides a 1.5 m cable and an 800 mm sensing distance?
A: The GTHN615V has a 1.5 m cable and reaches 800 mm with the F100R in long-distance mode. The 2 m GTHN620V reaches 700 mm in the same mode.
Q5: Does the GTHN605V still reach 900 mm if I switch the F100R to high-speed mode?
A: The 900 mm rating applies in long-distance mode. In high-speed mode, the GTHN605V is rated for 350 mm. Use the rating for the selected mode when setting the gap between the heads.
Q6: If I use an F85RN, does the detecting distance change with cable length?
A: All four models have the same F85RN ratings within each mode. Long-distance mode provides 590 mm and high-speed mode (H-SP) provides 160 mm, so you can select the length that fits the vacuum-side cable route.
Q7: Does Ø1.0 mm refer to the target or the fiber?
A: It is the min. detectable object diameter. The standard detectable object diameter is Ø1.2 mm. The cable measures Ø2.9 mm overall, and the glass fiber bundle measures Ø1.5 mm.
Q8: How much room do I need at a bend inside the chamber?
A: All four models have a min. bend radius of 30 mm. Maintain that radius or larger wherever the cable turns along a fixture or chamber wall.
Q9: Which components does the +350°C rating cover?
A: The −30 to +350°C ambient temperature rating applies to these four vacuum-side fiber units. Use the separate temperature ratings for the flange, atmospheric-side fiber, and amplifier when specifying the system.
Q10: Which fiber can I cut to length on site?
A: The FT7VGBC is the 2 m cut-to-length fiber for the atmospheric side of the flange. On the vacuum side, select the GTHN model with the required 0.5, 1, 1.5, or 2 m length.