FAQ
Q1: Can these fibers detect wafers inside a vacuum chamber?
A: Yes. All four are flange-coupled through-beam units for the vacuum side. Position the two heads opposite each other across the wafer path so the wafer interrupts the beam when present.
Q2: How do I choose between the GTHN705V, GTHN710V, GTHN715V, and GTHN720V?
A: Choose the GTHN705V for 0.5 m, GTHN710V for 1 m, GTHN715V for 1.5 m, or GTHN720V for 2 m of vacuum-side fiber. Then check the sensing gap for the amplifier and mode you plan to use.
Q3: Which thread should I use for the fixture, M4 or M8?
A: The sensing head has a 20 mm long M4 × 0.7 mm threaded section. The M8 thread belongs to the Ø10 mm clamping ring at the flange end.
Q4: How far apart can I place the heads with the 1 m GTHN710V and an F100R?
A: The rated gap is 850 mm in F100R long-distance mode (ELr) and 300 mm in high-speed mode (HIS). If you switch modes without moving the heads, use the 300 mm rating to set their spacing.
Q5: Which combination provides a 2 m cable and a 700 mm sensing distance?
A: Use the GTHN720V with the F100R in long-distance mode. Switching the F100R to high-speed mode gives a detecting distance of 220 mm with the same fiber unit.
Q6: Do all four models have the same range with an F85RN?
A: All four reach 140 mm in high-speed mode (H-SP). In long-distance mode, the GTHN705V reaches 565 mm and the other three models reach 560 mm.
Q7: How does the GTHN705V head differ from the M4 head on the GTHN605V?
A: The GTHN705V has a straight, 20 mm long M4 × 0.7 mm threaded section. The GTHN605V has an M4 body thread and an M2.6 tip thread. For a 0.5 m cable, choose the head that matches the threaded mounting hole in the fixture.
Q8: What cable diameter and bend radius should I allow for?
A: The cable has an OD of Ø2.9 mm and contains a Ø1.5 mm glass fiber bundle. Allow a bend radius of at least 30 mm with any of the four models.
Q9: Does the +350°C rating apply to the entire assembly?
A: The −30 to +350°C ambient temperature rating applies to the vacuum-side fiber unit. Use the separate ratings for the flange, atmospheric-side fiber, and amplifier.
Q10: How do I select fiber length on each side of the flange?
A: On the vacuum side, select the GTHN model that fits the cable route. On the atmospheric side, the FT7VGBC is a 2 m cut-to-length fiber that can be trimmed to reach the amplifier.