Close
Search
Banner Banner
Products
請選擇分類
TAKEX_GTHN705V

M4 Flange-Coupled Vacuum Through-Beam Fiber Units

  • TAKEX GTHN705V, GTHN710V, GTHN715V, and GTHN720V are flange-coupled vacuum through-beam fibers with straight M4 heads for wafer detection. The 0.5, 1, 1.5, and 2 m models reach 900, 850, 800, and 700 mm, respectively, in F100R long-distance mode. The fiber units are rated for −30 to +350°C.
  • Brand TAKEX Takenaka Engineering Co., Ltd.
Features
  • Wafer detection inside a vacuum chamber: Mount the transmitting and receiving heads opposite each other. A wafer interrupts the beam as it enters the gap, indicating its presence.
  • Straight M4 threaded head: The sensing head has a 20 mm long M4 × 0.7 mm threaded section. At the other end of the fiber, the flange clamping ring measures Ø10 mm and has an M8 thread.
  • Four vacuum-side cable lengths: The GTHN705V, GTHN710V, GTHN715V, and GTHN720V have 0.5, 1, 1.5, and 2 m cables, respectively. Choose the length that fits the route inside the chamber.
  • Sensing distance by amplifier mode: With the F100R, the 1 m GTHN710V reaches 850 mm in long-distance mode and 300 mm in high-speed mode.
  • Glass fiber in stainless steel spiral tubing: The vacuum-side fiber unit is rated for ambient temperatures of −30 to +350°C. Allow a bend radius of at least 30 mm when routing the cable along the chamber wall.
Specification
ItemSpec.
ModelsGTHN705V
GTHN710V
GTHN715V
GTHN720V
Detection methodThrough-beam
Location / connectionVacuum side / flange
Vacuum-side fiber length L (m)GTHN705V: 0.5
GTHN710V: 1
GTHN715V: 1.5
GTHN720V: 2
Sensing head styleStraight, threaded
Head thread (size × pitch)M4 × 0.7 mm
Threaded head length (mm)20
Flange clamping ring (OD / thread)Φ10 mm / M8
F100R long-distance mode (mm)GTHN705V: 900
GTHN710V: 850
GTHN715V: 800
GTHN720V: 700
F100R high-speed mode (mm)GTHN705V: 350
GTHN710V: 300
GTHN715V: 250
GTHN720V: 220
F85RN long-distance mode (mm)GTHN705V: 565
GTHN710V: 560
GTHN715V: 560
GTHN720V: 560
F85RN high-speed mode (H-SP) (mm)140
F80R long-distance mode (mm)GTHN705V: 480
GTHN710V: 450
GTHN715V: 430
GTHN720V: 380
F80R high-speed mode (mm)GTHN705V: -
GTHN710V: -
GTHN715V: -
GTHN720V: 210
F70R / F70AR detecting distance (mm)GTHN705V: 270
GTHN710V: 250
GTHN715V: 240
GTHN720V: 210
XF12R-A long-distance mode (mm)240
XF12R-A high-speed mode (H-SP) (mm)100
Standard detectable object diameter (mm)Φ1.2
Detectable object diameter, min. (mm)Φ1.0
Fiber / protective tubeGlass / stainless steel spiral tube
Cable OD / glass fiber bundle diameter (mm)Φ2.9 / Φ1.5
Bend radius, min. (mm)30
Fiber unit ambient temperature (°C)−30 to +350

Specification notes

  • Dimension L runs from the tip of the sensing head to the far end of the fiber unit. Allow room for a 30 mm bend radius when laying out the cable route.
  • Detecting distance is the gap between the transmitting and receiving heads. Match the fiber model, amplifier, and operating mode to the table. A dash indicates that no distance is listed for that combination.
  • The Φ1.2 mm standard and Φ1.0 mm min. values describe detectable object diameter. If wafer thickness determines your selection, verify the sensing conditions for that thickness separately.
FAQ

Q1: Can these fibers detect wafers inside a vacuum chamber?
A: Yes. All four are flange-coupled through-beam units for the vacuum side. Position the two heads opposite each other across the wafer path so the wafer interrupts the beam when present.


Q2: How do I choose between the GTHN705V, GTHN710V, GTHN715V, and GTHN720V?
A: Choose the GTHN705V for 0.5 m, GTHN710V for 1 m, GTHN715V for 1.5 m, or GTHN720V for 2 m of vacuum-side fiber. Then check the sensing gap for the amplifier and mode you plan to use.


Q3: Which thread should I use for the fixture, M4 or M8?
A: The sensing head has a 20 mm long M4 × 0.7 mm threaded section. The M8 thread belongs to the Ø10 mm clamping ring at the flange end.


Q4: How far apart can I place the heads with the 1 m GTHN710V and an F100R?
A: The rated gap is 850 mm in F100R long-distance mode (ELr) and 300 mm in high-speed mode (HIS). If you switch modes without moving the heads, use the 300 mm rating to set their spacing.


Q5: Which combination provides a 2 m cable and a 700 mm sensing distance?
A: Use the GTHN720V with the F100R in long-distance mode. Switching the F100R to high-speed mode gives a detecting distance of 220 mm with the same fiber unit.


Q6: Do all four models have the same range with an F85RN?
A: All four reach 140 mm in high-speed mode (H-SP). In long-distance mode, the GTHN705V reaches 565 mm and the other three models reach 560 mm.


Q7: How does the GTHN705V head differ from the M4 head on the GTHN605V?
A: The GTHN705V has a straight, 20 mm long M4 × 0.7 mm threaded section. The GTHN605V has an M4 body thread and an M2.6 tip thread. For a 0.5 m cable, choose the head that matches the threaded mounting hole in the fixture.


Q8: What cable diameter and bend radius should I allow for?
A: The cable has an OD of Ø2.9 mm and contains a Ø1.5 mm glass fiber bundle. Allow a bend radius of at least 30 mm with any of the four models.


Q9: Does the +350°C rating apply to the entire assembly?
A: The −30 to +350°C ambient temperature rating applies to the vacuum-side fiber unit. Use the separate ratings for the flange, atmospheric-side fiber, and amplifier.


Q10: How do I select fiber length on each side of the flange?
A: On the vacuum side, select the GTHN model that fits the cable route. On the atmospheric side, the FT7VGBC is a 2 m cut-to-length fiber that can be trimmed to reach the amplifier.