FAQ
Q1: Can I use these units if only one side of the target is accessible?
A: Yes. The GXHN405V and GXHN410V emit light and collect the reflection through the same sensing head. Both optical paths are on the accessible side of the target.
Q2: How do I choose between GXHN405V and GXHN410V?
A: Choose GXHN405V for a 0.5 m main cable or GXHN410V for a 1 m main cable. Head dimensions and rated sensing distances match when both use the same listed amplifier and mode.
Q3: Will the 4 mm head screw into an M4 tapped hole?
A: These models have a smooth cylindrical head with a 4 mm outside diameter. For an M4 threaded mount, compare the GXHN705V and GXHN710V reflective vacuum fiber units.
Q4: Does the 0.5 m or 1 m length include the flange-side branches?
A: Dimension L ends at the near end of the splitter body, measured from the sensing face. The splitter and its two branches have separate dimensions and require additional installation space.
Q5: How is the split sensing face arranged?
A: A 0.15 mm stainless steel partition divides the 2.0 mm glass fiber bundle into two semicircular sections. One transmits light and the other collects the reflection from the same sensing position.
Q6: Which amplifier modes cover a 100 mm head-to-target gap?
A: The F100R long-distance rating is 180 mm and the F85RN long-distance rating is 110 mm. Their high-speed ratings are 80 mm and 25 mm, respectively. Check the actual target at the intended position.
Q7: What range can I expect with an existing F70R amplifier?
A: Both fibers are rated for 35 mm with the F70R and a 50 × 50 mm sheet of white drawing paper. To reuse a fixture, check the gap from the sensing face to the target surface, then test with the actual part.
Q8: What is the min. detectable object diameter, and does it apply at 180 mm?
A: Detecting a 1.0 mm target at 180 mm requires a test with the actual target. The min. detectable object diameter is 1.0 mm, and 180 mm is the F100R long-distance rating.
Q9: What bend radius and temperature range apply inside the chamber?
A: Allow a cable bend radius of at least 50 mm. The −30 to +350 °C ambient range applies to the vacuum-side fiber unit. Use the individual temperature ratings for the flange, atmospheric-side fiber, and amplifier.
Q10: Which fiber can I cut to fit the run to the amplifier?
A: Choose the 0.5 m or 1 m fiber for the vacuum side. Use the FT7VGBC cut-to-length fiber on the atmospheric side for the run from the flange to the amplifier.