FAQ
Q1: How do GXHN705V and GXHN710V differ?
A: The GXHN705V has a 0.5 m main cable, and the GXHN710V has a 1 m main cable. They share the same mounting thread and sensing distance for each listed amplifier and mode.
Q2: Can I use these units if there is no room for a receiver opposite the target?
A: Yes. Each unit emits light and collects the reflection through the same sensing face. The fixture only needs space for a head on one side of the target.
Q3: What should I check when replacing a 4 mm cylindrical fiber head?
A: Check how the fixture holds the head. GXHN705V and GXHN710V have M4 × 0.7 mm threads. GXHN405V and GXHN410V have smooth 4 mm diameter cylindrical heads.
Q4: Which threads are used at the sensing head and the flange?
A: The sensing head has an M4 × 0.7 mm thread. Each of the two flange-side branches has an M8 clamping ring with a 10 mm outside diameter.
Q5: What does the cable length cover, and which section can I cut to fit?
A: The 0.5 m or 1 m dimension runs from the sensing face to the near end of the splitter. Select the vacuum-side model by that dimension. Use FT7VGBC on the atmospheric side for a cut-to-length run to the amplifier.
Q6: Which high-speed mode covers a 75 mm gap?
A: The F100R is rated for 80 mm in high-speed mode (HIS), making it a candidate for a 75 mm gap. The F85RN is rated for 25 mm in H-SP mode. Verify the 75 mm gap with the actual target before setting the mounting position.
Q7: What target is used for the 35 mm F70R rating?
A: The reference target is a 50 × 50 mm sheet of white drawing paper. Use the 35 mm rating as a reference and verify the range if your target differs in size, material, or surface finish.
Q8: Which model is used to detect glass substrates in a vacuum chamber?
A: The GXHN710V can detect display glass substrates from above a roller conveyor. Plan the route for its 1 m vacuum-side main cable, then use the actual glass to set the head-to-target distance.
Q9: What is the min. detectable object diameter, and does it apply at 180 mm?
A: Both units have a min. detectable object diameter of 1.0 mm. The 180 mm figure is the F100R long-distance rating. Verify a 1.0 mm target at 180 mm if the installation requires both conditions.
Q10: What temperature and bend radius apply inside the chamber?
A: Both vacuum-side fiber units are rated for −30 to +350 °C ambient and require a cable bend radius of at least 50 mm. Use the individual temperature ratings for the relay flange, atmospheric-side fiber, and amplifier.