FAQ
Q1: When should I choose the TAKEX GXZV505BJ?
A: Choose this side-view convergent reflective fiber optic unit for short-range glass detection when the sensing location requires heat resistance. The fiber unit is rated for ambient temperatures up to +250°C and works with a separate fiber amplifier.
Q2: Which face of the sensing head should point toward the glass?
A: Aim the flat face with the optical window at the glass. The same window emits light and receives the reflection, so the opposite side of the glass can remain clear.
Q3: How far can the glass be from the head when using an F70R?
A: With a 50 × 50 mm clear glass plate, 0.5 mm thick, the detecting distance is 0–5 mm from the optical window to the glass surface. Verify the distance with your own glass if its dimensions differ.
Q4: Should I use high-speed or long-distance mode on an F80R?
A: Both modes cover 0–5 mm with the GXZV505BJ. For a part that passes the head quickly, high-speed mode gives the F80R a response time of 190 μs max. Long-distance mode has a response time of 1.8 ms max.
Q5: Which modes can I use on an F85RN or F100R?
A: Use long-distance or high-speed (H-SP) mode on the F85RN. On the F100R, use long-distance (ELr) or high-speed (HIS) mode. Each of these settings provides a detecting distance of 0–5 mm.
Q6: Can the amplifier go in the same 250°C location as the head?
A: The +250°C ambient rating applies to the GXZV505BJ fiber unit. Install the amplifier within its own operating temperature range. For example, a single F85RN amplifier is rated for −25 to +55°C.
Q7: How much space does the head need, and what is the mounting hole spacing?
A: The head measures 20 × 18 × 5 mm and has two M2 tapped through holes on 7 mm centers. Allow additional space on the cable exit side for the fibers and the bend.
Q8: Does the 1 m cable dimension include the head and amplifier-side fittings?
A: The dimensional drawing shows 1000 mm from the end of the sleeve behind the head to the start of the amplifier-side fitting. Include the end hardware when calculating the overall installation space.
Q9: What do the Ø1.1 mm and Ø2.8 mm dimensions refer to?
A: Ø1.1 mm is the diameter of the glass fiber bundle. Ø2.8 mm is the outside diameter of the cable. Use the cable diameter when sizing a routing channel.
Q10: How much bend radius should I allow around a fixture?
A: Maintain a radius of at least 25 mm. Where the cable route changes direction at a corner, leave room for a smooth curve that maintains this radius throughout the bend.